Rate Constant Calculator
The rate constant k is the number that turns a rate law into a rate, and there are four different ways to get it depending on what you measured. This calculator covers all four: the Arrhenius equation from activation energy and temperature, the rate law from a measured rate and concentrations, the integrated rate law from concentration readings over time (with half-life), and a two-temperature prediction from a k you already know. Pick the tab that matches your data.
For study and lab planning. The units of k depend on the overall reaction order; the tool reports them for each method. Two honest limits: the Arrhenius tab always prints its answer with s⁻¹ because it cannot know your reaction order, so read A in the units of your own k; and in the Rate law tab a [B] of exactly 0 is ignored, as if the field were blank.
Quick Answer
With the pre-filled Arrhenius values (A = 1 × 1013 s⁻¹, Ea = 100 kJ/mol, T = 300 K) the rate constant is k = 3.8710 × 10−5 s⁻¹, because only 3.8710 × 10−18 of molecules carry enough energy to react. The other tabs answer the same question from other data: a measured rate of 0.02 M/s at [A] = 0.5 M with order 2 gives k = 8.0000 × 10−2 M⁻¹ s⁻¹, and 1.0 M falling to 0.25 M in 100 s gives a first-order k = 1.3863 × 10−2 s⁻¹ with a 50.00 s half-life.
Key takeaways
- k is fixed by temperature, not by concentration. Change the temperature and you get a different k; change the starting amounts and k stays put.
- Match the tab to your data: Arrhenius for A, Ea and T; Rate law for a measured rate; Integrated for two concentration readings; Two-temperature to move a known k to a new temperature.
- The units of k change with overall order: M s⁻¹ (zeroth), s⁻¹ (first), M⁻¹ s⁻¹ (second). Quoting k without units is the most common kinetics error.
- Ea goes in as kJ/mol and temperature as kelvin (or Celsius on the Arrhenius tab). The tool converts both, which removes the two classic unit traps.
- Quick Answer
- How to use the rate constant calculator
- Which method to use, and what k actually is
- The four formulas behind the tabs
- Worked examples, checked against this exact tool
- The units of k change with order
- Why temperature dominates the rate
- Half-life only behaves for first order
- What competing calculators miss
- Honest limits of this tool
- Frequently asked questions
- Add This Calculator to Your Website
- References
How to use the rate constant calculator
Start by picking the tab that matches the data you actually have, then enter the values and click Calculate. Results stay hidden until you calculate, and switching tabs clears the previous result.
- Arrhenius: enter the frequency factor A, the activation energy in kJ/mol, and the temperature (kelvin, or Celsius with the unit selector). Best when a problem gives you A and Ea directly.
- Rate law: enter a measured rate with the concentrations and orders from the rate law. Add the optional [B] and its order only when the rate law has a second reactant.
- Integrated: pick the reaction order, then enter the starting concentration, the concentration at time t, and the elapsed seconds. You get k, the half-life, and the percent consumed.
- Two-temperature: enter a known k₁, the activation energy, and both temperatures in kelvin. You get k₂ and the percent change, labelled faster or slower.
Every tab validates before it calculates. A missing frequency factor reports “Enter the frequency factor A.”, a temperature at absolute zero reports “Temperature must be above absolute zero (0 K).”, and the Integrated tab refuses a later concentration that is not smaller than the starting one, because a growing concentration cannot produce a decay constant.
Which method to use, and what k actually is
k is the proportionality constant in rate = k[A]m[B]n: the rate you would observe if every concentration were 1 M, scaled by temperature. The four tabs are four doors into the same constant, and the right door is the one your data fits.
If your question is really “how fast is the concentration changing,” that is the rate itself, not k. A rate of reaction calculator works that average-rate side of the problem (concentration change over a time interval) and never solves for k. This page starts where that one stops: it assumes you want the constant, with its order-dependent units attached. Concentrations here are in mol/L throughout; if your lab figures start as a mass dissolved in a volume, run them through the molarity concentration calculator first so the rate law gets proper molar values.
| You have | Tab | You get |
|---|---|---|
| A, Ea and T | Arrhenius | k plus the fraction of molecules with enough energy |
| A measured rate, concentrations, orders | Rate law | k, its units, and the overall order |
| [A]₀, [A] at time t, and t | Integrated | k, half-life, and percent consumed |
| k at one temperature, Ea, two temperatures | Two-temperature | k at the second temperature plus the percent change |
The four formulas behind the tabs
All four tabs run textbook chemical kinetics, the same forms taught in general chemistry and set out in the LibreTexts integrated rate laws chapter and the OpenStax Chemistry 2e integrated rate laws section. R is 8.314 J/(mol·K) everywhere; the exact CODATA value is 8.314462618, and the rounded 8.314 used here and in most textbooks changes nothing at the precision these tools report.
Rate law: k = rate ÷ ([A]m × [B]n)
Integrated, zeroth: k = ([A]₀ − [A]t) ÷ t
Integrated, first: k = ln([A]₀ ÷ [A]t) ÷ t
Integrated, second: k = (1 ÷ [A]t − 1 ÷ [A]₀) ÷ t
Two-temperature: k₂ = k₁ × e((Ea ÷ R)(1 ÷ T₁ − 1 ÷ T₂))
The two-temperature form is the Arrhenius equation with A cancelled out: write k at both temperatures, divide one by the other, and A disappears. That is why the tab never asks for A. The same cancellation is what makes the form, covered in the LibreTexts Arrhenius equation page, the standard way to predict a rate at a temperature nobody has measured yet.
Worked examples, checked against this exact tool
Each tab opens pre-filled with its own worked example, and every figure below is a real run of the calculator above. Change a tab’s values back to these and the outputs match digit for digit.
| Tab | Inputs | Result |
|---|---|---|
| Arrhenius | A = 1 × 1013, Ea = 100 kJ/mol, T = 300 K | k = 3.8710 × 10−5 s⁻¹ |
| Rate law | rate 0.02 M/s, [A] = 0.5 M, order 2 | k = 8.0000 × 10−2 M⁻¹ s⁻¹, overall order 2 |
| Rate law with B | rate 0.036 M/s, [A] = 0.3 M order 1, [B] = 0.2 M order 2 | k = 3.0000 M⁻² s⁻¹, overall order 3 |
| Integrated, first order | [A]₀ = 1.0 M to 0.25 M in 100 s | k = 1.3863 × 10−2 s⁻¹, t½ = 50.00 s, 75.0% consumed |
| Integrated, zeroth order | [A]₀ = 1.0 M to 0.4 M in 60 s | k = 1.0000 × 10−2 M s⁻¹, t½ = 50.00 s |
| Integrated, second order | [A]₀ = 1.0 M to 0.5 M in 50 s | k = 2.0000 × 10−2 M⁻¹ s⁻¹, t½ = 50.00 s |
| Two-temperature | k₁ = 0.005 at 298.15 K, Ea = 100 kJ/mol, T₂ = 310 K | k₂ = 2.3372 × 10−2, 367.44% faster |
One warning the two-temperature row earns: some worked examples online quote k₂ = 0.00500772 for these exact inputs. That figure comes from treating Ea as 100 J/mol instead of 100 kJ/mol, a factor-of-1000 slip in the exponent. This tool takes kJ/mol and converts, so 0.023372 is the answer consistent with a 100 kJ/mol barrier.
The units of k change with order
The units of k are whatever makes the rate come out in M/s, so they follow the overall order n as M(1−n) s⁻¹. The Rate law tab builds the unit from the overall order automatically, and the Integrated tab prints the unit for the order you selected.
| Overall order | Units of k | Half-life | Half-life depends on [A]₀? |
|---|---|---|---|
| 0 | M s⁻¹ | [A]₀ ÷ 2k | Yes |
| 1 | s⁻¹ | ln(2) ÷ k | No, constant |
| 2 | M⁻¹ s⁻¹ | 1 ÷ (k[A]₀) | Yes |
| 3 | M⁻² s⁻¹ | (Rate law tab reports the units; the Integrated tab covers orders 0 to 2) | Yes |
Two display quirks to know about, both preserved from the tool’s general unit formula. For overall order 0 the Rate law tab prints “M^1 s⁻¹” rather than “M s⁻¹”: same unit, written straight from M(1−n). And the Arrhenius tab always labels its answer s⁻¹, because A, Ea and T alone do not reveal the order. Read the Arrhenius answer in whatever units your A carried.
Why temperature dominates the rate
Temperature sits inside an exponent, so small changes multiply k instead of nudging it. Holding A = 1 × 1013 and Ea = 100 kJ/mol, the Arrhenius tab returns these values across a 30 K span:
The bars are drawn to scale, and the pattern is the point: each 10 K step multiplies k by roughly 3.4 to 4.0 here, not by a fixed addition. The classroom rule that “the rate doubles every 10 degrees” is this same exponential seen at a lower barrier, around 50 to 60 kJ/mol. At 100 kJ/mol the doubling rule badly understates the sensitivity, which is why a 12 K rise in the two-temperature example (298.15 K to 310 K) already multiplies k by about 4.7. The NIST CODATA listing for the molar gas constant gives the exact R behind these numbers.
Half-life only behaves for first order
Only first-order reactions have a half-life that stays constant as the reaction runs. For first order, t½ = ln(2) ÷ k: 50.00 s in the worked example, and it would still be 50.00 s if you started at 0.5 M or 0.1 M.
Zeroth and second order tie the half-life to the starting concentration, as the Purdue half-life notes set out: zeroth order gives t½ = [A]₀ ÷ 2k (start lower, finish the half sooner), and second order gives t½ = 1 ÷ (k[A]₀) (start lower, and each halving takes longer than the last). That behaviour is a diagnostic, not a nuisance: if your measured half-life drifts as concentration falls, the reaction is not first order, no matter how clean a single first-order fit looks. First-order decay is exponential decay, the same e−kt curve the exponential growth calculator draws with the sign flipped, which is why radioactive decay and first-order kinetics share one set of formulas.
What competing calculators miss
Kinetics tools online tend to cover one door each, and the seams show when your data does not match the door you landed on:
- Arrhenius-only tools (Softonic, Savvy Calculator, CalculatorAtoZ): they compute k from A, Ea and T and stop. Savvy Calculator’s own worked example takes Ea in J/mol (75,000 J/mol), so a student holding 75 kJ/mol from a textbook gets a wildly wrong answer unless they convert first. Nothing on those pages touches a measured rate or concentration data.
- Interactive Arrhenius visualizers (FIRGELLI): genuinely good for seeing the exponential respond to sliders, and they document the two-temperature form, but the tool set is still Arrhenius-only: no rate-law solve, no integrated solve.
- Rate-law-only tools (Calculator Ultra): the formula k = R ÷ (Am Bn) matches our Rate law tab, with a sound example (0.02 over 1.5 × 2² gives 0.00333). But there is no Arrhenius mode, no integrated mode, and no half-life anywhere on the page.
- Half-life specialists (MolDraw, EverydayBudd): strong on decay curves and order tables, and EverydayBudd even fits data to find the order. Neither starts from A and Ea, and neither predicts k at a new temperature.
- The gap this page fills: all four standard routes to k on one page, with Ea taken in kJ/mol and converted internally, correct units per overall order, a half-life on every integrated run, and step-by-step working under each result so the number can be checked rather than trusted.
Honest limits of this tool
Four things this calculator does not do, stated plainly so nobody has to discover them mid-assignment:
- It does not find the reaction order for you. The Integrated tab applies the order you select. Fitting a full concentration-time series to decide between orders needs a plot or regression, which is a different tool.
- The second-order integrated form assumes one reactant (rate = k[A]², or A + B with equal concentrations), the standard textbook case in the OpenStax chapter 12 summary. Two reactants at different concentrations need the logarithmic two-species form, which is not one of the tabs.
- A is treated as temperature-independent, the usual Arrhenius simplification over modest ranges. Over hundreds of kelvin, A drifts and the two-temperature prediction drifts with it.
- The Rate law tab ignores a [B] of 0 or a negative value instead of erroring, exactly as if the field were blank. A filled [B] with a blank order, on the other hand, is an error: “Enter the order in B (or clear [B]).”
- An Ea of 0 in the two-temperature tab reads as no change, however the temperatures differ: with Ea = 0 the predicted k₂ equals k₁, so the tool reports “0.00% faster” even when T₂ differs from T₁: the correct Arrhenius result for a barrierless reaction, not a temperature effect.
Frequently asked questions
The proportionality constant in the rate law, rate = k[A]ᵐ[B]ⁿ. It sets how fast a reaction runs at a given temperature, and it does not change when concentrations change. Change the temperature and k changes, which is what the Arrhenius and Two-temperature tabs are for.
Multiply the frequency factor by e raised to minus Ea over RT: k = A × e^(−Ea ÷ RT), with T in kelvin and Ea in J/mol inside the exponent. With A = 1 × 10¹³ s⁻¹, Ea = 100 kJ/mol and T = 300 K, the Arrhenius tab gives k = 3.8710 × 10⁻⁵ s⁻¹. The tab accepts Ea in kJ/mol and multiplies by 1000 for you.
They depend on the overall order n and follow M^(1−n) s⁻¹. Zeroth order gives M s⁻¹, first order gives s⁻¹, and second order gives M⁻¹ s⁻¹. The Rate law tab prints M^1 s⁻¹ for an overall order of 0, which is the same unit as M s⁻¹ written in the general format.
Use the integrated rate law for the reaction order. Zeroth order: k = ([A]₀ − [A]ₚ) ÷ t. First order: k = ln([A]₀ ÷ [A]ₚ) ÷ t. Second order: k = (1 ÷ [A]ₚ − 1 ÷ [A]₀) ÷ t. The Integrated tab applies the form you pick and reports the half-life alongside k.
Zeroth order: t½ = [A]₀ ÷ 2k. First order: t½ = ln(2) ÷ k, which is constant and does not depend on the starting concentration. Second order: t½ = 1 ÷ (k[A]₀). Only the first-order half-life stays the same as the reaction proceeds.
Inside the Arrhenius exponent Ea must be in J/mol, because R = 8.314 J/(mol·K). Both Arrhenius tabs take Ea in kJ/mol and multiply by 1000 internally, so entering 100 for a 100 kJ/mol barrier is correct here. Tools that expect J/mol need 100000 for the same barrier.
Kelvin, always. The Arrhenius tab accepts either: pick the Celsius option and it adds 273.15 before calculating. The Two-temperature tab takes kelvin only, and both tabs reject temperatures at or below 0 K.
Exponentially, through e^(−Ea ÷ RT). For Ea = 100 kJ/mol with A = 1 × 10¹³, k rises from 9.7141 × 10⁻₆ at 290 K to 1.4109 × 10⁻⁴ at 310 K, about 14.5 times larger for a 20 K rise. The popular rule that rates double every 10 degrees only holds for activation energies near 50 to 60 kJ/mol.
No. k is a positive constant for a real reaction. If a calculation returns a negative k, the data or the assumed order is wrong: check for a later concentration that is higher than the starting one, swapped readings, or a mis-set order. The Integrated tab rejects growth instead of returning a negative k.
The pre-exponential factor in the Arrhenius equation: roughly how often molecules collide in an orientation that can react. It carries the same units as k, is found experimentally, and is treated as temperature-independent over modest ranges, which is why the two-temperature form can cancel it out.
Add This Calculator to Your Website
Embed this calculator on your own site with the code below. Pick a size to preview it live, then copy the code.
Powered by Calculator Zilo
References
- Chemistry LibreTexts. Arrhenius Equation (k = Ae^(−Ea/RT), the two-temperature form ln(k1/k2), A in the same units as k, R = 8.314 J/mol K, T in kelvin). Accessed October 24, 2026.
- Chemistry LibreTexts. Integrated Rate Laws (integrated forms and half-lives for zeroth, first and second order, with the first-order half-life worked example). Accessed October 24, 2026.
- OpenStax, Rice University. Chemistry 2e, 12.4 Integrated Rate Laws (second-order integrated law 1/[A] = kt + 1/[A]0 and the order-by-order half-life behaviour). Accessed October 24, 2026.
- OpenStax, Rice University. Chemistry 2e, Chapter 12 Summary (12.4 integrated rate laws and half-life by order; 12.5 collision theory and the Arrhenius relation between k, activation energy and temperature). Accessed October 24, 2026.
- Purdue University, Department of Chemistry. Half Lives (half-life equations for zero, first and second order and how a half-life is converted to a rate constant). Accessed October 24, 2026.
- National Institute of Standards and Technology (NIST). CODATA Value: Molar Gas Constant (R = 8.314462618 J mol−1 K−1, exact; the tool uses the standard textbook rounding 8.314). Accessed October 24, 2026.
